Home / Blog / Industry News & Regulations
Industry News & Regulations

Merseyrail's £3.5m Tunnel Repairs: What They Reveal About Concrete Waterproofing and Ageing Infrastructure

November 17, 2026
4 views
Merseyrail's £3.5m Tunnel Repairs: What They Reveal About Concrete Waterproofing and Ageing Infrastructure

Network Rail has completed a £3.5 million programme of concrete repairs, strengthening and waterproofing across four Victorian railway tunnels beneath Liverpool.


The work, carried out on Merseyrail's Northern Line, demonstrates the importance of maintaining ageing infrastructure, particularly where water ingress threatens structural condition and the reliable operation of essential services.


With extensive concrete repairs and thousands of resin injection points forming part of the programme, the project also highlights how targeted remedial work can help extend the service life of existing structures.


For infrastructure owners, facilities managers and those responsible for maintaining concrete assets, there are several important lessons.


What happened during the Merseyrail tunnel repairs?


The programme focused on four underground tunnels between Brunswick and Liverpool Central, with engineering works beginning on 11 October 2026.

Following a 27-day closure, the railway reopened on 7 November.


According to Network Rail, the completed programme involved:

  • 92m2 of deteriorated concrete removed ahead of reinstatement.
  • 6,500 holes drilled for waterproofing injections.
  • 115 weep holes installed to direct water towards the track drainage system.
  • 1,688m2 of tunnel wall waterproofed.
  • More than 50 workers involved in delivering the improvements.


The works were undertaken alongside upgrades to railway power control equipment.


A principal objective was to reduce water entering the Victorian tunnels and interfering with the electrified third rail system used to power Merseyrail trains.


The scale of the intervention demonstrates how water ingress can create operational problems beyond the immediate condition of the structure.


Why is water ingress such a concern in ageing infrastructure?


Water ingress is a common challenge in underground structures, particularly where construction materials, joints and waterproofing systems have been exposed to decades of environmental conditions.


Over time, moisture can enter through cracks, construction joints and other vulnerable areas.


Depending on the structure and its exposure conditions, prolonged water ingress can contribute to several problems.


Deterioration of reinforced concrete


Where water and oxygen reach embedded steel reinforcement, corrosion may develop. As corrosion products accumulate, their expansion can place pressure on the surrounding concrete, potentially contributing to cracking, delamination and spalling.


If deterioration progresses, the structure may require more extensive investigation and repair.


Damage to surrounding materials and equipment


Water ingress can also affect finishes, electrical equipment and mechanical installations. In the Merseyrail tunnels, protecting the third rail electrical system was a central reason for the waterproofing programme.


In other environments, such as basements, plant rooms and underground car parks, persistent water ingress can similarly disrupt building operations and increase maintenance requirements.


Increasing maintenance costs


A relatively localised leak can become more expensive to address if the underlying cause is left unresolved. Repeated temporary repairs may also prove ineffective where the water pathway has not been properly identified.


For asset owners, early investigation can help establish whether a defect requires localised sealing, a wider waterproofing intervention or structural remedial work.


How was resin injection used in the Merseyrail tunnels?


One of the most significant elements of the programme involved resin injection waterproofing. As reported by Concrete Connect, specialist teams injected low-viscosity polyurethane resin into sections of the Victorian brick tunnel lining.


The process involved drilling injection points through which the resin could be introduced into the structure. The treatment was intended to create a barrier against incoming water, with weep holes providing controlled drainage towards the track bed.


Resin injection is an established specialist technique for controlling water ingress, although the choice of resin and injection method depends on the defect, substrate and conditions encountered.


For example, polyurethane resin systems may be specified for certain active leaks, while other injection materials may be more appropriate where structural crack bonding is required.

These distinctions matter.


A waterproofing treatment designed to control water movement should not automatically be regarded as a structural repair.


Before specifying injection works, the cause of the defect, the movement characteristics of the crack and the intended performance of the repair should be understood.


Concrete repair and waterproofing often need to work together


The Merseyrail programme combined waterproofing with the removal and reinstatement of deteriorated concrete.


Concrete Connect also reported that work within the Central Tunnel involved hydro-blasting and sprayed concrete reinstatement across an approximately 14-metre section. This illustrates an important consideration for maintaining older structures: waterproofing and concrete repair may address different aspects of the same problem.


Where concrete has already deteriorated, controlling water ingress alone may not restore the required condition of the affected material. Equally, replacing damaged concrete without addressing the source of persistent water ingress can leave the structure vulnerable to further deterioration.


An effective remedial strategy may therefore involve:

  • Investigating the extent and causes of concrete deterioration.
  • Identifying cracks, joints and water ingress pathways.
  • Removing and reinstating defective concrete where necessary.
  • Specifying suitable waterproofing or injection systems.
  • Establishing appropriate inspection and maintenance arrangements.


The exact sequence and specification must reflect the condition and requirements of the individual structure.


What can infrastructure owners learn from the project?


The Merseyrail works offer several useful considerations for organisations responsible for maintaining ageing concrete assets.


1. Investigate defects before selecting repair methods


Visible cracking and water ingress do not always reveal the full extent of a problem.

Cracks can result from different mechanisms, including movement, loading, shrinkage and deterioration.

Their significance depends on factors such as location, width, depth, activity and the function of the structure.

A suitable condition assessment helps determine which defects require monitoring, further investigation or remedial intervention.


2. Consider the consequences of water ingress


A leak may appear relatively minor when assessed in isolation.

However, its consequences can be much greater where moisture affects essential equipment, occupied spaces or structural components.

For underground railway infrastructure, the consequences can include disruption to passenger services.

For commercial buildings, residential developments and industrial facilities, water ingress can affect operational continuity and long-term maintenance expenditure.


3. Plan repairs around operational requirements


The Merseyrail programme required a temporary railway closure to allow the work to be undertaken.

Other structures may need to remain operational throughout remedial works.

Car parks, hospitals, occupied residential buildings and industrial facilities can all present access and programme constraints.

Understanding these requirements early helps contractors and asset managers develop a realistic repair strategy.


4. Match repair materials to the environment


Repair systems must be appropriate for their intended use.

This is particularly important for structures exposed to groundwater, chemicals, aggressive environments or repeated movement.

Material compatibility, substrate condition and the required performance of the completed repair should all inform the specification.


Where else are these repair principles relevant?


Although the Merseyrail project involved railway tunnels, many of the underlying challenges are also encountered in other concrete structures.


Underground car parks: Water ingress through cracks and joints can contribute to deterioration, corrosion and damage to occupied or operational areas.

Basements and below-ground structures: Defects in waterproofing systems or construction joints can allow groundwater to enter, requiring investigation and targeted remedial treatment.

Water-retaining structures and bunds: Cracking and leakage can compromise containment performance, making accurate defect mapping and appropriate material selection particularly important.

Commercial and residential buildings: Concrete deterioration, movement joints and water penetration can create ongoing maintenance problems where defects are not addressed effectively.

Each environment presents different technical requirements, but the underlying principle remains consistent: the condition of the structure and the cause of the defect should guide the repair.


Specialist concrete repair and waterproofing from MPS Concrete Solutions


At MPS Concrete Solutions, we provide specialist concrete repair and structural waterproofing services across commercial, residential and infrastructure environments.

With 25+ years of combined experience, our team works on a range of concrete defects and water ingress problems, including:


Our approach begins with understanding the condition of the structure and the requirements of the proposed repair.

Whether dealing with water ingress in a basement, cracking within a concrete tank or deterioration affecting an existing structure, appropriate investigation and material selection are essential.


Concerned about cracking or water ingress?

If you are responsible for a concrete structure showing signs of deterioration, cracking or persistent water ingress, MPS Concrete Solutions can discuss the problem and the appropriate next steps.


Contact MPS Concrete Solutions: https://mpsconcrete.com/


Sources and further reading

This article discusses publicly reported infrastructure works. MPS Concrete Solutions was not involved in the Merseyrail project.

Reviewed by Jerry Blears, Director (LinkedIn), MPS Concrete Solutions.

Share this article:

Need Expert Assistance?

Contact our team for specialized waterproofing and concrete repair solutions.

Call 01223 850450