Our Product Suppliers
We partner with industry-leading manufacturers to provide the best solutions for your concrete repair and waterproofing needs. Explore our product range by supplier.
What this page is for. It lists the product ranges our site teams install, with the manufacturers' data sheets, so that clients, engineers and specifiers can check what is going into a repair before it starts. MPS is a contractor, not a merchant: we do not sell these products or ship them. If you are looking for a product to buy, the manufacturer links on each supplier page go to their stockists. If you have a defect and want to know which system it needs, start with the table below.
Which Product Type Does Your Problem Need?
The defect decides the product category; the survey decides the product. These are the pairings we use most, with the standard the product has to meet.
| What you are seeing | Product category | Specified under | Read more |
|---|---|---|---|
| Spalled concrete, rust staining, exposed bars | Reinforcement primer plus class R3/R4 structural repair mortar | BS EN 1504-7 and BS EN 1504-3 | Spalling repair guide |
| Water running through a crack or construction joint | Water-reactive polyurethane injection resin; acrylic gel for damp joints | BS EN 1504-5 | Resin injection |
| Dry, dormant structural crack | Low-viscosity rigid epoxy injection resin | BS EN 1504-5 | Resin injection |
| Damp or wet basement or cellar walls | Cementitious tanking slurry and fillet mortar (Type A), or cavity drain membrane, channel and pump (Type C) | BS 8102:2022 | Tanking cost guide |
| Car park deck leaking onto the level below | Traffic-bearing deck waterproofing (polyurethane or fast-cure PMMA) with anti-skid broadcast | BS EN 1504-2 | Car park waterproofing |
| Carbonated facade, balconies or soffits | Anti-carbonation coating over completed repairs | BS EN 1504-2 | Repair cost guide |
| Pipes, ducts or cables passing through a wall or floor | Hydrophilic or resin penetration seals; tested fire-stopping where the wall is a compartment line | BS 8102:2022 and BS EN 1366-3 | Penetration sealing |
Not sure which row you are in? and we will tell you what it is and whether it needs a survey. If a site visit is needed, the survey is free.
Sika
10 Products Available
Mapei
16 Products Available
Fosroc
36 Products Available
Master Builders
11 Products Available
Newton Waterproofing
18 Products Available
Remmers
20 Products Available
Weber
13 Products Available
How We Choose Repair and Waterproofing Products
These are the product ranges our teams work with on site, listed so that clients, engineers and specifiers can read the data sheets before work starts. We do not sell products online; each one is selected against the survey findings and the standard that governs the repair — which matters more than the brand.
- Repair mortars are classified under BS EN 1504-3 as R1–R4. Structural repairs to columns, beams, soffits and car park decks need class R3 or R4; R1 and R2 are for cosmetic and non-structural work only. The class, not the product name, is the first thing to check on a quote.
- Reinforcement primers protect cleaned steel before the mortar goes on (BS EN 1504-7). Skipping this step is the most common reason patch repairs fail.
- Injection resins and grouts are chosen under BS EN 1504-5 by what the crack needs: rigid epoxy to restore strength in a dry, dormant crack; flexible or hydrophilic polyurethane to stop water through a live, wet crack or joint.
- Protective coatings — anti-carbonation and deck coatings — are specified under BS EN 1504-2 for the exposure: carbonation resistance on façades, crack-bridging and abrasion resistance on car park decks.
- Below-ground waterproofing — cementitious tanking, membranes and cavity drain systems — is designed to BS 8102:2022 as Type A, B or C protection, often in combination.
Across the 7 manufacturers above we work most with Sika, for which we are a specified applicator, and use the other ranges listed here where a system suits the job better or the project specification names it.
Not sure which system your structure needs? Our spalling repair guide, basement tanking cost guide and concrete repair cost guide explain the options, or see the services these products are used in.
Three things to check on any product named in a quote
- The class, not the brand. A repair mortar's data sheet states its BS EN 1504-3 class. If a structural repair is quoted with an R2 mortar, the quote is cheaper because the product is wrong.
- The applicator approval. Manufacturers' warranties on waterproofing and deck systems normally depend on the installer being an approved applicator for that system. Ask for the certificate, not the logo.
- The substrate the data sheet assumes. Every product on these pages assumes a prepared substrate — sound, clean, at the right moisture content and within the temperature window. A quote that prices the product but not the preparation is pricing half the job.
Next step: if you have a defect, or call 01223 850450 and we will tell you which category it falls into. If you are a specifier who needs a particular system installed, tell us the product and we will confirm whether we are approved for it.
Reviewed by Jerry Blears, Director (LinkedIn), MPS Concrete Solutions. Last reviewed October 2026.